HYDRAULIC ELECTRIC CONTROL VALVE EN600X
A. HYDRAULIC ELECTRIC CONTROL VALVE Structure and Purpose
A hydraulic operated valve with a solenoid valve together as the pilot valve, used in the pipeline system for automatic control to control open-close of the system remotely upon an electric signal, It has accurate and quick response to the execution of remote operation and control. It has adjustable valve close speed, and can be closed stably without any pressure fluctuation. The solenoid valve can use either AC220V or DC24V power and is available with normal open or close type. EN600X Hydraulic Electric Control Valve is features by the small volume, light weight, easy repair and operation, safety and reliability, long duration. And it can replace both gate and butterfly valves in the large electric operation system.
B. HYDRAULIC ELECTRIC CONTROL VALVE Brief Figure of Structure
EN600X HYDRAULIC ELECTRIC CONTROL VALVE
C. HYDRAULIC ELECTRIC CONTROL VALVE External and Connection Dimensions
D. HYDRAULIC ELECTRIC CONTROL VALVE Schematic Diagram of Installation
| DN(mm) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
400 |
450 |
500 |
600 |
700 |
| L |
180 |
180 |
180 |
203 |
203 |
235 |
280 |
360 |
400 |
455 |
585 |
650 |
800 |
860 |
915 |
980 |
1075 |
1230 |
1300 |
| PN10 |
D |
105 |
115 |
135 |
145 |
160 |
180 |
195 |
215 |
245 |
280 |
335 |
390 |
440 |
500 |
565 |
615 |
670 |
780 |
895 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
180 |
210 |
240 |
295 |
350 |
400 |
460 |
515 |
565 |
620 |
725 |
840 |
| PN16 |
D |
105 |
115 |
135 |
145 |
160 |
180 |
195 |
215 |
245 |
280 |
335 |
405 |
460 |
520 |
580 |
640 |
705 |
840 |
910 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
180 |
210 |
240 |
295 |
355 |
410 |
470 |
525 |
585 |
650 |
770 |
840 |
| PN25 |
D |
105 |
110 |
135 |
145 |
160 |
180 |
195 |
230 |
270 |
300 |
360 |
425 |
485 |
550 |
610 |
660 |
730 |
840 |
955 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
190 |
220 |
250 |
310 |
370 |
430 |
490 |
550 |
600 |
660 |
770 |
875 |
| H |
342 |
342 |
342 |
395 |
395 |
405 |
430 |
510 |
560 |
585 |
675 |
730 |
760 |
840 |
910 |
1070 |
1135 |
1270 |
1460 |
| H1 |
250 |
250 |
250 |
278 |
278 |
298 |
315 |
350 |
365 |
420 |
450 |
470 |
490 |
526 |
570 |
610 |
665 |
725 |
865 |
Note: Either elastic seat ring sealed gate valve or butterfly valve can be selected in the schematic of installation. Recommend to select the butterfly valve in case of =DN350
E. HYDRAULIC ELECTRIC CONTROL VALVE Main Technical Features
| Nominal Pressure |
1.0MPA |
1.6MPA |
2.5MPA |
| Shell test pressure |
1.5MPA |
2.4MPA |
3.75MPA |
| Sealed test pressure |
1.1MPA |
1.76MPA |
2.75MPA |
| Suitable temperature |
≤80℃ |
| Suitable medium |
water |