PRESSURE DISCHARGE & SUSTAIN VALVE EN500X
A. PRESSURE DISCHARGE & SUSTAIN VALVE Structure and purpose
EN500X Pressure Discharge & Sustain Valve is used in the pipeline system to prevent of surpassing pressure or to keep the pressure of it, to reduce the water hammer's shock after the pump is closed and also used as a water hammer remover in the large water supply system. A self cleaning filter screen is placed on the inlet of the valve's control system, which stops the suspension grains of the bigger specific gravity and diameter from going into the system by means of the bigger specific gravity of the fluid to ensure the main valve's water supply pressure at the upstream at the set value, and to get the system circulated smoothly without any resistance. This valve features by sensitive open-close, safety, reliability, stable motion and long duration.
B. PRESSURE DISCHARGE & SUSTAIN VALVE Brief Figure of Structure
1. Small Ball Valve
2. Pilot Valve
3. Small Ball Valve
4. Small Ball Valve
5. Needle Valve
1.Small Ball Valve
2. Pilot Valve
3. Small Ball Valve
4. Small Ball Valve
5. Needle Valve
6. Small Ball Valve
C. PRESSURE DISCHARGE & SUSTAIN VALVE External and Connection Dimensions
D. PRESSURE DISCHARGE & SUSTAIN VALVE Schematic Diagram of Installation
| DN(mm) |
20 |
25 |
32 |
40 |
50 |
65 |
80 |
100 |
125 |
150 |
200 |
250 |
300 |
350 |
400 |
450 |
500 |
| L |
180 |
180 |
180 |
203 |
203 |
235 |
285 |
360 |
400 |
455 |
585 |
650 |
800 |
860 |
915 |
980 |
1075 |
| PN10 |
D |
105 |
115 |
135 |
145 |
160 |
180 |
195 |
215 |
245 |
280 |
335 |
390 |
440 |
500 |
565 |
615 |
670 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
180 |
210 |
240 |
295 |
350 |
400 |
460 |
515 |
565 |
620 |
| PN16 |
D |
105 |
115 |
135 |
145 |
160 |
180 |
195 |
215 |
245 |
280 |
335 |
405 |
460 |
520 |
580 |
640 |
705 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
180 |
210 |
240 |
295 |
355 |
410 |
470 |
525 |
585 |
650 |
| PN25 |
D |
105 |
110 |
135 |
145 |
160 |
180 |
195 |
230 |
270 |
300 |
360 |
425 |
485 |
550 |
610 |
660 |
730 |
| D1 |
75 |
85 |
100 |
110 |
125 |
145 |
160 |
190 |
220 |
250 |
310 |
370 |
430 |
490 |
550 |
600 |
660 |
| H |
550 |
550 |
550 |
610 |
610 |
625 |
645 |
750 |
808 |
864 |
1135 |
1185 |
1325 |
1385 |
1445 |
1325 |
1430 |
| H1 |
460 |
460 |
460 |
516 |
516 |
520 |
538 |
596 |
655 |
710 |
805 |
855 |
955 |
990 |
1030 |
905 |
960 |
Note: Either elastic seat ring sealed gate valve or butterfly valve can be selected in the schematic of installation. Recommend to select the butterfly valve in case of =DN350
E. PRESSURE DISCHARGE & SUSTAIN VALVE Main Technical Features
| Nominal Pressure |
1.0MPa |
1.6MPa |
2.5MPa |
| Shell test pressure |
1.5MPa |
2.4MPa |
3.75MPa |
| Sealed test pressure |
1.1MPa |
1.76MPa |
2.75MPa |
| Suitable temperature |
≤80℃ |
| Suitable medium |
water |